Featured Products: SR75 Series
Description:
Short Circuit Protected COTS Solid State Relays
Application note describing the application and technical benefits of the following features:
- Short Circuit and Overload Current Protection: prevents damage to
system components, assemblies and system wiring from overload current or short
circuit conditions
- Optical Isolation: isolates signals and logic circuits from load
transients, and eliminates ground loops and signal ground noise
- Broad Switching Range: SR75-1- 60 Vdc @ 1.5 Adc, SR75-2- 300 Vdc @ 0.75
Adc or 120 Vrms @ 0.5 Amps
- Power FET Output: No voltage offset with a linear on-resistance for low
voltage drop reducing power dissipation
- Low Off-State Leakage and High Dielectric Strength: for high off-state
impedance and safety and protection of circuits
Introduction:
The SR75 is a DC solid state relay with built-in short circuit and overload
current protection. The operating voltage range is from zero to 60 Vdc (SR75-1),
zero to 300 Vdc or 120 Vrms AC (SR75-2) when connected with a diode bridge. This
series provides protection of AC or DC loads against damage from overload
currents. The SR75 offers protection against short circuit and overload currents
by continuously monitoring the instantaneous load current and the output switch
junction temperature. If either condition exceeds predetermined limits the relay
will turn-off and remain off until it is reset by removing the overload
condition and cycling the input control voltage. This action mimics a resetable
circuit breaker but with a turn-off time of micro-seconds (ms) in the presence
of short circuit currents. The SR75 can respond to large excess currents fast
enough to prevent serious damage to the relay, system wiring, or other system
components.
This application note describes the operational considerations when using this
relay and the technical benefits of the features offered.
Input/Control
The SR75 is an optically isolated solid state relay that uses light emitting
diodes (LED's) to generate light. The light from the LEDs is detected by light
sensitive devices creating a voltage that powers an isolated output switching
device. The light generated from the LED is directly proportional to the current
that flows through the LED. Figure 1 is a simplified functional diagram of an
optically isolated solid state relay. This diagram shows the input drive and the
output Field Effect Transistor (FET) switch. With optical isolation, loads can
be connected to the output with no electrical reference to the input. The loads
can float and be switched in the ground buss, the power buss or anywhere in
between. Optical isolation prevents conduction of electrical noise from the
output to the input which can cause false signals.
The input LED is driven by a current source for consistency of the switch
performance over temperature. Figure 2 is a family plot of the voltage current
transfer characteristic curves for an LED shown at three different temperatures.
If the drive source for the LED were a voltage source, and the LED were driven
at 1.25 Vdc at 25_C, the current would be about 12.5 mA. Now if the temperature
were to change to - 40_C and the drive voltage remained at 1.25 Vdc the LED
current would change to about 5 mA. An additional change of temperature to 100_C
would change the LED current to about 24 mA. This example illustrates how a
change in operating temperature of the LED could cause large changes in the
light emitted from the LED and the voltage generated for the output switch,
affecting the FET turn-on characteristics. Attempting to overdrive the LED with
a large input voltage/current to always ensure adequate drive to the output
switch would then result in excessive power dissipation in the relay input
circuit and would decrease the allowable power that could be used to drive the
load.
If ,however, the drive source for the LED were a current source, then voltage
changes caused by temperature effects would reflect only small input drive
demand as the temperature changed but the LED current would remain fixed. The
input drive current would always be adequate and input power dissipation would
be fixed and consistent with load requirements.
Teledyne's SR75 series is designed with a current regulator input drive circuit
to optimize the relay operation over temperature. A plot of the input transfer
function is shown in Figure 3. The current as a function of voltage rises
quickly around 3.0 volts and is relatively flat as the voltage increases. For
input voltages between 3.8 and 6.0 volts the relay can be driven directly from a
voltage source (TTL) with no external components. If the input drive is greater
than 6.0 Vdc, the current source would still maintain the LED current but power
would increase rapidly as the input drive voltage increased. Since the power
dissipated is finite, the power consumed in the input must be subtracted from
the allowable power switched in the load. Input drive voltages greater than 6.0
volts requires a series input resistor to limit the power dissipation on the
input.
Figure 4 is a nomograph that allows quick determination of the value of the
required series resistor when the input drive voltage exceeds 6.0 Volts.
Alternatively, use the following formula to calculate the series resistor value:
Rs = (V-6) / 11 mA
Short Circuit Protection
The short circuit and overload current protection is implemented with a current
sense and with a junction temperature monitor for maximum effectiveness. Figure
5 is a block diagram of the SR75-1 and the SR75-2 showing the protection circuit
implementation.
The instantaneous load current is monitored and the protection will be triggered
if the load current exceeds a predetermined value for a specified time duration.
The higher the current the shorter the time for the protection to be activated.
Figure 6 is a plot of the overload current response transfer function.
This curve displays the current level and time duration that will trigger a
turn-off from the overload circuit. It also shows different curves for 25_C,
85_C, 105_C and -55_C operations. The response is completely controlled by the
current sense in the very short time response area. As time increases on the
response curve, the importance of the junction temperature intensifies. This is
true until in the area where time is long the response is equally controlled by
the junction temperature measurement and the current monitor. When the junction
temperature reaches a predetermined value the relay will turn-off. The trip
point of the junction temperature is set such that it would only be reached if
the output load conditions were abnormal. The trip point is low enough that
there is a reasonable margin before electrical damage to the switch could occur.
The curve in Figure 6 covers overload response times from 0.01 seconds to
basically infinity. For very large short circuit currents different response
curves apply.
There are two different conditions of short circuit current flow that can exist
each with a different response. One condition is when the SR75 solid state relay
is off and is turned on into a short with no current limiting. This condition is
shown in Figure 7(a). The initial conditions for this response is that the
voltage is set at 300 Vdc and is applied to the output. The relay is then
turned-on with no limiting impedance. It takes the SR75 relay approximately 120
ms to respond to the short circuit current and turn-off. During that time the
peak current rises to about 5.0 Amps. The turn-off after that is very quick (in
the order of a few microseconds).
The second condition for a short circuit current is where the SR75 series is on
and is conducting up to the rated load current when a short circuit occurs. The
transient response for this condition is shown in Figure 7(b). The initial
conditions for this plot is 300 Vdc is switched directly across the output with
no current limiting impedance while the SR75 is on and conducting 0.6 Adc. In
the Figure 7(a) response, the peak current is in the area of 5 Adc. In the case
of a short circuit ocurring while the relay is conducting, the peak current is
more than 10 times that value; but the time duration of the transient current is
approximately 2 ms. Neither of these conditions will cause permanent damage to
the SR75. Figures 7(a) and 7(b) data are intended to show typical response times
and current magnitudes to instantaneous, short circuit currents. Actual
responses would depend on circuit conditions, load parameters, current flow and
applied voltage.
When the SR75-1 or the SR75-2 detect a short circuit or current overload, a
latch is triggered in the output drive circuit that turns the output FET off.
The latch will remain set until the turn-on voltage to the output FET is
removed. Removal of the input drive voltage will reset the latch off. Reapplying
an input turn-on voltage will then turn the SR75 solid state relay back on.
Typical SR75-1, SR75-2 Applications:
Servo Systems
Instrumentation
Robots and Drones
Control Systems
Alarm/Warning Systems
Liquid & Gas Pumps
Thermal Control Systems
Automated Test
Light Control Systems
Control Panels
Programmable Controllers
Defrosters
Audio Visual Controls & Displays
Typical SR75-1, SR75-2 Loads:
Motors DC or AC
Transducers
Solenoids
Lights
Relays
Power FETs For DC or Bi-Directional Loads
Heaters
Power Triacs, or SCRs For AC Loads
SR75 Series Wiring Configuration
Below are typical connections for interfacing the SR75-1 and the SR75-2 into
either AC or DC Loads.